Fluid Reservoir
Holds the fluid used to inflate the penile cylinders and is positioned internally in the pelvic area.
AMS 700 penile implant is a primium three-piece inflatable penile implant for men with persistent erectile dysfunction when tablets, injections or other non-surgical treatments are no longer providing satisfactory erections.
AMS 700™ Consultation
New Delhi, India
Urologist, Andrologist and Penile Implant Surgeon
AMS 700 Penile Implant
The AMS 700™ Penile Implant is a three-piece, fluid-filled inflatable penile prosthesis used as a surgical treatment for men with persistent erectile dysfunction. The complete system is implanted inside the body and allows the patient to create and release an erection using a concealed pump.
Holds the fluid used to inflate the penile cylinders and is positioned internally in the pelvic area.
Two cylinders are placed inside the penis and fill with fluid when an erection is required.
A concealed pump in the scrotum controls inflation and includes a mechanism for deflation.
AMS 700 penile implant surgery cost in Delhi, India at New Delhi Andrology is ₹8,50,000. Treatment is planned personally by Dr. Vijayant Govinda Gupta after a detailed andrology, penile anatomy and surgical evaluation.
Dr. Vijayant Govinda Gupta is a specialist urologist, andrologist and high-volume penile implant surgeon based in New Delhi, India. His clinical practice focuses on advanced treatment for erectile dysfunction, penile implant surgery, revision implant procedures and prosthetic urology. Every patient undergoes a detailed evaluation of medical history, penile anatomy, previous treatments and expectations before an implant is selected.
His approach combines extensive surgical experience with individualised treatment planning, transparent cost discussion and structured postoperative care. He has undertaken advanced international training in the USA, South Korea, China and Turkey, gaining exposure to modern penile implant techniques, complex implant surgery and patient-specific treatment planning.
View the professional certification and advanced penile implant training credentials of Dr. Vijayant Govinda Gupta.
Watch specialist videos about inflatable penile implants, AMS 700™ surgery, implant function, treatment selection and postoperative recovery.
Compare company background, implant construction, regulatory status, warranty, cylinder expansion, pump operation, infection-protection technology, reservoir design and clinic pricing before AMS 700™ or Infla10® Pulse™ AX surgery.
Comparison
Key FactorsTechnical and practical points patients should understand before surgery. |
Boston Scientific
AMS 700™Three-piece inflatable penile prosthesis with multiple cylinder and pump configurations. ₹8.5 Lakh |
Rigicon
Infla10® Pulse™ AXThree-piece inflatable penile prosthesis with anatomical length and girth expansion. ₹8.5 Lakh |
|---|---|---|
|
Manufacturer
|
Boston Scientific Global medical-device company and manufacturer of the AMS penile prosthesis portfolio. | Rigicon Urological-prosthesis manufacturer offering malleable and inflatable penile implants. |
|
Implant Architecture
|
Three-piece inflatable system Two intracavernosal cylinders, a scrotal pump and a fluid-filled reservoir. | Three-piece inflatable system Two intracavernosal cylinders, a scrotal pump and a fluid-filled reservoir. |
|
U.S. FDA Status
|
FDA PMA Approved AMS 700 Series product line approved under FDA PMA N970012. | U.S. Clearance Not Verified FDA clearance for the Infla10 AX was not located in the reviewed FDA records. Confirm current country-specific registration before surgery. |
|
Manufacturer Warranty
|
Boston Scientific Limited Warranty Availability and claim coverage vary by geography, product labeling and current manufacturer policy. | Product Replacement Lifetime Warranty In countries where offered, it covers qualifying device replacement for the original patient. Surgical and hospital expenses are excluded. |
|
Cylinder Expansion
|
Model-dependent expansion LGX is designed for length and girth expansion; CX provides controlled girth expansion; CXR is designed for narrower or scarred anatomy. | Anatomical length and girth expansion AX cylinders provide longitudinal expansion in addition to girth expansion. Expansion depends on individual anatomy. |
|
Pump and Deflation
|
TENACIO™ or MS Pump™ options TENACIO is engineered for different pumping styles and includes a prominent one-press deflation control with tactile feedback. | Infla10® Pulse™ pump Designed for rapid cylinder inflation and single-press deflation. |
|
Infection-Protection Surface
|
InhibiZone™ antibiotic treatment available Selected AMS 700 configurations have built-in rifampin and minocycline antibiotic surface treatment. | HydroShield™ hydrophilic coating Hydrophilic surface designed to allow dipping in a surgeon-selected aqueous antimicrobial solution. |
|
Durability Design
|
Parylene-coated cylinders Parylene coating is used to reduce friction and mitigate cylinder fatigue during repeated use. | Multi-layer cylinder construction Infla10 cylinders use a layered construction developed for rigidity, expansion and durability. |
|
Reservoir Design
|
Flat and spherical reservoir options AMS Conceal™ flat reservoir and spherical reservoir configurations are available. | Adaptive reservoir with lock-out valve Multiple reservoir volumes are available, with a lock-out valve designed to reduce involuntary inflation. |
|
Models and Sizes
|
LGX, CX and CXR configurations Multiple cylinder lengths and model options for different expansion goals and anatomical needs. | Six AX cylinder lengths AX cylinders are listed in 12, 15, 18, 20, 22 and 24 cm lengths. |
|
New Delhi Andrology Price
|
₹8.5 Lakh Approximate AMS 700™ penile implant surgery package. | ₹8.5 Lakh Approximate Infla10® Pulse™ AX penile implant surgery package. |
Clear answers to commonly asked questions about AMS 700™ implant surgery, cost, suitability, recovery and device use.
The AMS 700™ is a three-piece inflatable penile implant with two cylinders, a fluid reservoir and a scrotal pump. The pump is used to create rigidity, while the release mechanism returns the implant to a softer state.
The approximate cost is ₹8.5 lakh at Govinda MediCenter and approximately ₹10 lakh at Apollo Spectra Hospital. Final pricing depends on implant selection, anatomy, hospital category and surgical complexity.
It may be considered for men with erectile dysfunction who have not achieved satisfactory results with medicines, injections, vacuum devices or other treatments. Suitability also depends on health, anatomy and pump-handling ability.
AMS 700™ can be inflated and deflated using an internal pump. A malleable implant uses two bendable rods that remain firm and are positioned manually without a pump or reservoir.
Surgery duration and hospital stay vary according to anatomy, fibrosis, previous procedures and anaesthesia requirements. Many patients require short observation or an overnight hospital stay.
Activation begins only after the surgeon confirms satisfactory wound healing and reduced swelling. The patient is then taught how to inflate and deflate the device during a follow-up appointment.
Book a confidential consultation with Dr. Vijayant Govinda Gupta to discuss your erectile dysfunction history, previous treatments, penile anatomy, implant options, surgery cost and expected recovery.
Urologist, andrologist and penile implant surgeon in New Delhi, India.